Surface Mount Transient Voltage Suppressors
High temperature stability and high reliability conditions
FEATURES
- Junction passivation optimized design passivated anisotropic rectifier technology.
- TJ = 175℃ capability suitable for high reliability and automotive requirement.
- Available in uni-directional polarity only.
- Low leakage current.
- Low forward voltage drop.
- High surge capability.
- Meets ISO16750-2 surge specification(varied by test condition).
- Meets MSL-1, per J-STD-020, LF maximum peak of 245℃.
- AEC-Q101 qualified.
- Compliant to RoHS directive 2011/65/EU and in accordance to WEEE 2002/96/EC.


ELECTRICAL CHARACTERISTICS | ||||||||
Part Number | VR | IT | IR@VR | VBR@IT | VC@IPP | IPP | ||
Uni-polar | V | mA | μA@25°C | μA@175°C | min(V) | max (V) | V | A |
SM6S10A | 10.0 | 5 | 5 | 250 | 11.1 | 12.3 | 17.0 | 271.0 |
SM6S11A | 11.0 | 5 | 5 | 150 | 12.2 | 13.5 | 18.2 | 253.0 |
SM6S12A | 12.0 | 5 | 5 | 150 | 13.3 | 14.7 | 19.9 | 231.0 |
SM6S13A | 13.0 | 5 | 5 | 150 | 14.4 | 15.9 | 21.5 | 214.0 |
SM6S14A | 14.0 | 5 | 5 | 150 | 15.6 | 17.2 | 23.2 | 198.0 |
SM6S15A | 15.0 | 5 | 5 | 150 | 16.7 | 18.5 | 24.4 | 189.0 |
SM6S16A | 16.0 | 5 | 5 | 150 | 17.8 | 19.7 | 26.0 | 177.0 |
SM6S17A | 17.0 | 5 | 5 | 150 | 18.9 | 20.9 | 27.6 | 167.0 |
SM6S18A | 18.0 | 5 | 5 | 150 | 20.0 | 22.1 | 29.2 | 158.0 |
SM6S20A | 20.0 | 5 | 5 | 150 | 22.2 | 24.5 | 32.4 | 142.0 |
SM6S22A | 22.0 | 5 | 5 | 150 | 24.4 | 26.9 | 35.5 | 130.0 |
SM6S24A | 24.0 | 5 | 5 | 150 | 26.7 | 29.5 | 38.9 | 118.0 |
SM6S26A | 26.0 | 5 | 5 | 150 | 28.9 | 31.9 | 42.1 | 109.0 |
SM6S28A | 28.0 | 5 | 5 | 150 | 31.1 | 34.4 | 45.4 | 101.0 |
SM6S30A | 30.0 | 5 | 5 | 150 | 33.3 | 36.8 | 48.4 | 95.0 |
SM6S33A | 33.0 | 5 | 5 | 150 | 36.7 | 40.6 | 53.3 | 86.0 |
SM6S36A | 36.0 | 5 | 5 | 150 | 40.0 | 44.2 | 58.1 | 79.0 |
Note:
①. For all types maximum VF=1.9V at IF=100A measured on 8.3ms single half sine-wave or equivalent square wave, duty cycle=4 pulses per minute maximum.
②.Surge waveform:10/1000μs
VR: Stand-off voltage — Maximum voltage that can be applied VBR: Breakdown voltage
VC: Clamping voltage — Peak voltage measured across the suppressor at a specified IPP IR: Reverse leakage current
IT: Test current