{"id":935,"date":"2020-12-18T09:31:47","date_gmt":"2020-12-18T09:31:47","guid":{"rendered":"http:\/\/www.unictron.com\/protection\/?page_id=935"},"modified":"2023-05-16T06:27:52","modified_gmt":"2023-05-16T06:27:52","slug":"pxxxxsb","status":"publish","type":"page","link":"https:\/\/www.unictron.com\/protection\/circuit-protection-components\/thyristor-surge-suppressors-tss\/tss-smd-type\/pxxxxsb\/","title":{"rendered":"PxxxxSB"},"content":{"rendered":"\n<p><strong>Thyristor Surge Suppresser<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-medium\"><a href=\"https:\/\/i2.wp.com\/www.unictron.com\/protection\/wp-content\/uploads\/sites\/3\/2020\/12\/P31B1542.jpg\"><img decoding=\"async\" width=\"300\" height=\"210\" src=\"https:\/\/i2.wp.com\/www.unictron.com\/protection\/wp-content\/uploads\/sites\/3\/2020\/12\/P31B1542-300x210.jpg?resize=300%2C210\" alt=\"\" class=\"wp-image-936\" srcset=\"https:\/\/i2.wp.com\/www.unictron.com\/protection\/wp-content\/uploads\/sites\/3\/2020\/12\/P31B1542.jpg?resize=300%2C210&amp;ssl=1 300w, https:\/\/i2.wp.com\/www.unictron.com\/protection\/wp-content\/uploads\/sites\/3\/2020\/12\/P31B1542.jpg?resize=1024%2C717&amp;ssl=1 1024w, https:\/\/i2.wp.com\/www.unictron.com\/protection\/wp-content\/uploads\/sites\/3\/2020\/12\/P31B1542.jpg?resize=768%2C538&amp;ssl=1 768w, https:\/\/i2.wp.com\/www.unictron.com\/protection\/wp-content\/uploads\/sites\/3\/2020\/12\/P31B1542.jpg?resize=1536%2C1075&amp;ssl=1 1536w, https:\/\/i2.wp.com\/www.unictron.com\/protection\/wp-content\/uploads\/sites\/3\/2020\/12\/P31B1542.jpg?resize=600%2C420&amp;ssl=1 600w, https:\/\/i2.wp.com\/www.unictron.com\/protection\/wp-content\/uploads\/sites\/3\/2020\/12\/P31B1542.jpg?w=2000&amp;ssl=1 2000w\" sizes=\"(max-width: 300px) 100vw, 300px\" data-recalc-dims=\"1\" \/><\/a><\/figure><\/div>\n\n\n<p>DO-214AA\/SMB Thyristor solid state protection thyristor protect telecommunications equipment such as modems, line cards, fax machines, and other CPE. This Series devices are used to enable equipment to meet various regulatory requirements including GR1089, ITUK.20, K.21 and K.45, IEC 60950, and TIA-968(formerly known as FCC Part 68).<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"is-layout-flex wp-container-3 wp-block-columns\">\n<div class=\"is-layout-flow wp-block-column\">\n<h2>Features<\/h2>\n\n\n\n<ul>\n<li>Excellent capability of absorbing transient surge<\/li>\n\n\n\n<li>Quick response to surge voltage<\/li>\n\n\n\n<li>Eliminates overvoltage caused by fast rising transients<\/li>\n\n\n\n<li>Solid-state silicon technology, non degenerative<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"is-layout-flow wp-block-column\">\n<h2>Application<\/h2>\n\n\n\n<ul>\n<li>Audio\/Video line<\/li>\n\n\n\n<li>Network and telecom<\/li>\n\n\n\n<li>Data lines and security systems<\/li>\n\n\n\n<li>Serial ports<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<p><strong>PART NUMBER AND ELECTRICAL PARAMETER <\/strong>@ T=25\u2103 RH = 45%-75%<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>PART NUMBER<\/strong><\/td><td><strong>V<sub>DRM<\/sub> <\/strong><strong>V<\/strong> <strong>Min.<\/strong><\/td><td><strong>I<sub>DRM<\/sub><\/strong> <strong>uA Max.<\/strong><\/td><td><strong>V<sub>S<\/sub> <\/strong><strong>V<\/strong> <strong>Max.<\/strong><\/td><td><strong>I<sub>S<\/sub><\/strong> <strong>mA<\/strong><\/td><td><strong>V<sub>T<\/sub> <\/strong><strong>V<\/strong> <strong>Max.<\/strong><\/td><td><strong>I<sub>T<\/sub> <\/strong><strong>A<\/strong><\/td><td><strong>I<sub>H<\/sub><\/strong> <strong>mA Min.<\/strong><\/td><td><strong>C<sub>O<\/sub><\/strong> <strong>pF Typ.<\/strong><\/td><\/tr><tr><td>P0060SB<\/td><td>6<\/td><td>5<\/td><td>15<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>40<\/td><td>80<\/td><\/tr><tr><td>P0080SB<\/td><td>6<\/td><td>5<\/td><td>25<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>40<\/td><td>80<\/td><\/tr><tr><td>P0150SB<\/td><td>15<\/td><td>5<\/td><td>25<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>40<\/td><td>80<\/td><\/tr><tr><td>P0300SB<\/td><td>25<\/td><td>5<\/td><td>40<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>40<\/td><td>80<\/td><\/tr><tr><td>P0640SB<\/td><td>58<\/td><td>5<\/td><td>77<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>120<\/td><td>60<\/td><\/tr><tr><td>P0720SB<\/td><td>65<\/td><td>5<\/td><td>88<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>120<\/td><td>60<\/td><\/tr><tr><td>P0900SB<\/td><td>75<\/td><td>5<\/td><td>98<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>120<\/td><td>55<\/td><\/tr><tr><td>P1100SB<\/td><td>90<\/td><td>5<\/td><td>130<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>120<\/td><td>55<\/td><\/tr><tr><td>P1300SB<\/td><td>120<\/td><td>5<\/td><td>160<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>120<\/td><td>55<\/td><\/tr><tr><td>P1500SB<\/td><td>140<\/td><td>5<\/td><td>180<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>120<\/td><td>60<\/td><\/tr><tr><td>P1800SB<\/td><td>170<\/td><td>5<\/td><td>220<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>120<\/td><td>60<\/td><\/tr><tr><td>P2300SB<\/td><td>190<\/td><td>5<\/td><td>260<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>120<\/td><td>55<\/td><\/tr><tr><td>P2600SB<\/td><td>220<\/td><td>5<\/td><td>300<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>120<\/td><td>50<\/td><\/tr><tr><td>P3100SB<\/td><td>275<\/td><td>5<\/td><td>350<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>120<\/td><td>45<\/td><\/tr><tr><td>P3500SB<\/td><td>320<\/td><td>5<\/td><td>400<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>120<\/td><td>40<\/td><\/tr><tr><td>P4200SB<\/td><td>400<\/td><td>5<\/td><td>520<\/td><td>800<\/td><td>4<\/td><td>2.2<\/td><td>\u226450<\/td><td>40<\/td><\/tr><tr><td colspan=\"9\">1\u3001Vs is measured at 100KV\/S <br>2\u3001Off-state capacitance is measured in V<sub>DC<\/sub>=2V,V<sub>RMS<\/sub>=1V,F=1MHz <br>3\u3001All measurements are made at an ambient temperature of 25\u2103<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p class=\"hide\"><a href=\"http:\/\/d3ua1wm7iroa4g.cloudfront.net\/protection\/wp-content\/uploads\/sites\/3\/2021\/04\/PxxxxSB.pdf\">Download datasheet in PDF format.<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Thyristor Surge Suppresser DO-214AA\/SMB Thyristor solid state protection thyristor protect telecommunications equipment such as modems, line cards, fax machines, and other CPE. This Series devices are used to enable equipment&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1667,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"spay_email":""},"_links":{"self":[{"href":"https:\/\/www.unictron.com\/protection\/wp-json\/wp\/v2\/pages\/935"}],"collection":[{"href":"https:\/\/www.unictron.com\/protection\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.unictron.com\/protection\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.unictron.com\/protection\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.unictron.com\/protection\/wp-json\/wp\/v2\/comments?post=935"}],"version-history":[{"count":6,"href":"https:\/\/www.unictron.com\/protection\/wp-json\/wp\/v2\/pages\/935\/revisions"}],"predecessor-version":[{"id":3485,"href":"https:\/\/www.unictron.com\/protection\/wp-json\/wp\/v2\/pages\/935\/revisions\/3485"}],"up":[{"embeddable":true,"href":"https:\/\/www.unictron.com\/protection\/wp-json\/wp\/v2\/pages\/1667"}],"wp:attachment":[{"href":"https:\/\/www.unictron.com\/protection\/wp-json\/wp\/v2\/media?parent=935"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}